Current location:
Homepage
/
/
/
Checks before starting the two-color pyrometer

News Center

Check category

Checks before starting the two-color pyrometer

(Summary description)In order to ensure the normal operation of the instrument is not affected by the environment, check the environment before starting the machine.

Checks before starting the two-color pyrometer

(Summary description)In order to ensure the normal operation of the instrument is not affected by the environment, check the environment before starting the machine.

Information

1. In order to ensure the normal operation of the instrument is not affected by the environment, check the environment before starting the machine. The temperature and relative humidity are the same as when the instrument is stored.

Wholesale High temperature pyrometer

2. If there is a temperature and humidity difference between the storage environment and the use environment of the instrument, for example, the storage environment temperature of the instrument is lower than the use environment temperature, it will cause condensation water on the surface of the instrument, which will lead to damage or short circuit of the internal components of the instrument.

3. When taking the instrument out of the packing box or storage rack, be careful not to bump all the protruding terminals on the panel.

4. For short-distance transportation of desktop equipment, use a suitable instrument vehicle. For long-distance transportation, the instrument must be packed in strict anti-vibration packaging.

5. In order to prevent the malfunction of the instrument caused by static electricity on the operator's body, an anti-static wristband must be worn when starting up and operating. When necessary, wear electrostatic gloves (finger cots), anti-static clothing, and anti-static shoes.

6. Confirm the power supply: Make sure the socket is powered. 2. Check the power supply: Use a multimeter to measure the zero wire and live wire, that is, "left zero and right fire" to check whether the voltage phase is normal. According to the use environment, check the voltage difference between the neutral wire and the ground wire. If the voltage difference is too large, the equipment shell will be charged. If a potential difference is generated, current will flow through different circuit paths. Generally, the potential difference is less than 2 volts and it will not have any effect.

7. In order to prevent the input voltage exceeding the required voltage of the instrument and cause the components to be overloaded and burned, it must be confirmed whether the power supply voltage is consistent with the power supply standard of the instrument. The power supply standard of the instrument is confirmed by checking the identification of the power interface of the instrument.

RECOMMEND NEWS

2022
12-02
小黑点

Measuring range of optical pyrometers

When the temperature to be measured is higher than the range that thermocouples can use, and where it is impossible or not suitable for installation of thermocouples, optical pyrometers can generally meet this requirement.
查看详情
2022
11-24
小黑点

What are the characteristics of industrial pyrometers

Pyrometers are available in two forms: 1) A device for measuring the temperature of the molten pool, including: a refractory mounting sleeve and an optical pyrometer;
查看详情
2022
11-17
小黑点

Fluorescent fiber optic temperature transmitter product introduction

Fluorescent optical fiber temperature transmitter is a multi-channel optical fiber temperature measurement device. The temperature measurement channel can be expanded according to the demand,
查看详情
迪凯光电

400-811-6877

Tel:027-8750 9386   027-8750 9105
Add:Dingye building C block, International Enterprise Center, Optics Valley Avenue, Wuhan China  
Fax:027-87745185   
Mail:dkoe@chinadikai.com