Current location:
Homepage
/
/
Instructions for using infrared thermometer

News Center

Check category

Instructions for using infrared thermometer

  • Categories:NEWS
  • Author:
  • Origin:
  • Time of issue:2021-01-06 11:42
  • Views:

(Summary description)In the current battle to prevent and control new pneumonia, human infrared thermometers are widely used in public places such as hospitals, airports, railway stations, docks, subway stations, and highway intersections as body temperature measurement equipment.

Instructions for using infrared thermometer

(Summary description)In the current battle to prevent and control new pneumonia, human infrared thermometers are widely used in public places such as hospitals, airports, railway stations, docks, subway stations, and highway intersections as body temperature measurement equipment.

  • Categories:NEWS
  • Author:
  • Origin:
  • Time of issue:2021-01-06 11:42
  • Views:
Information

The human body infrared thermometer is a photoelectric instrument that measures the infrared radiation of the measured object (the surface of the human body, the ear cavity, etc.) through a detector, and after appropriate correction, outputs the photoelectric instrument that displays the temperature of a certain part of the body. It is mainly divided into three types: infrared forehead thermometer, infrared ear thermometer, and infrared screening instrument. As an important medical instrument, human infrared thermometers play a key role in epidemic prevention and control.

In the current battle to prevent and control new pneumonia, human infrared thermometers are widely used in public places such as hospitals, airports, railway stations, docks, subway stations, and highway intersections as body temperature measurement equipment.

01.The human body infrared thermometer is a medical instrument and needs to be calibrated before use. At present, my country's existing technical specifications such as JJF1107 "Calibration Specification for Infrared Thermometers for Measuring Human Body Temperature" are used as the basis for measurement and testing of human infrared thermometers. After the measurement calibration is corrected, the measurement data is more accurate. If the calibration finds that the data of the measuring instrument is too large, the measurement repeatability is poor, and the performance is unstable, it is recommended to stop.

02.There are many types of human infrared thermometers, and there are certain differences in their design ideas, operating habits, and internal settings. Therefore, when using the human infrared thermometer, you should read the product manual carefully and be familiar with the basic functions of the instrument, which is conducive to the scientific and correct use of the measuring instrument.

03.The recommended ambient temperature given in most product manuals is (16~35)℃, and some manufacturers’ internal test data ambient temperature is (10~40)℃. In the outdoor environment where the ambient temperature is lower than 10℃, few manufacturers perform A large number of samples are tested. Therefore, when the ambient temperature is lower than 16°C, and there is strong convection and large temperature fluctuations, the data deviation of the human body thermometer will be large. From the principle of measurement, it is a normal phenomenon.
When measuring the human body temperature outdoors, it is recommended to measure it in a place where there is no strong convection, no strong radiation, non-high humidity, relatively constant temperature, and can be higher than 10℃. At the same time, it should be ensured that the thermometer is working under stable environmental conditions for a long time.

04.When following the specific attention to the details proposed in each product manual. Here we propose the basic operating specifications for using the thermometer: When measuring body temperature, please aim the measuring instrument (forehead thermometer) at the exact center of your forehead (above the center of your eyebrows and keep it vertical), and the measuring part should not be covered by hair, sweat, hats, etc. Please make sure that the measuring distance is (1~3) cm. Keep the same operating specifications, repeat the measurement twice within 1 minute, and the difference between the two measurement data is within 0.3 ℃, then the data can be accepted, otherwise you need to check and measure again.

05.The measured object of the human body infrared thermometer is the part of the human body targeted during the measurement. From the principle of measurement, especially for forehead thermometers, the environment where the measurement site is located will have a greater impact on the measurement results. For example, the temperature of the human body in the car is measured at a highway intersection. Due to the large temperature of the air-conditioning in the car and the large difference from the outdoor temperature, the temperature of the measured object will be too high. The personnel in the car and the measuring instrument should be at the same ambient temperature and in a thermal equilibrium state. The measurement data can only be credible when the measurement is performed under the high-speed intersection, when waiting in line for temperature measurement, it is recommended that the people in the car should drive the window in advance to ventilate, and the human body and the outside environment should be in thermal balance before measuring.

Wuhan Dikai Optoelectronics Technology Co., Ltd is specializing in infrared temperature measuring instruments.our main products are include infrared laser thermometer,high speed pyrometer,spot pyrometer,aluminum pyrometer,online pyrometer,fixed pyrometer,    Infrared Pyrometer,Infrared Thermometer,Fiber Optic Pyrometer,High Temperature Pyrometer,pyrometer thermometer,High temperature pyrometer,radiation pyrometer,digital pyrometer,ir pyrometer,two color pyrometer,infrared temperature sensor,laser pyrometer,optical pyrometer,dual wavelength pyrometer,non contact pyrometer etc.Welcome to contact us.

RECOMMEND NEWS

2024
04-16
小黑点

Exploring the Various Types of Aluminum Pyrometers

Dive into the world of aluminum pyrometers with this comprehensive guide that covers everything from basic principles to advanced applications. Discover the different types of aluminum pyrometers and
查看详情
2024
03-26
小黑点

Understanding Fiber Optic Pyrometers in Temperature Measurement Instruments

Learn about the technology behind fiber optic pyrometers and how they are used in temperature measurement instruments within the gas and liquid metrology industry.
查看详情
2024
03-19
小黑点

Exploring Common Challenges and Solutions in Using Fiber Optic Pyrometers for Temperature Measurement

Discover the ins and outs of utilizing fiber optic pyrometers for temperature measurement, including the most common challenges that users face and the solutions to overcome them. Dive deep into the w
查看详情
迪凯光电

400-811-6877

Tel:027-8750 9386   027-8750 9105
Add:Dingye building C block, International Enterprise Center, Optics Valley Avenue, Wuhan China  
Fax:027-87745185   
Mail:dkoe@chinadikai.com