Structure of a radiation pyrometer

  • Categories:Seminar
  • Author:
  • Origin:
  • Time of issue:2022-03-22 14:08
  • Views:

(Summary description)The radiation pyrometer is designed and manufactured according to the functional relationship between the radiation energy of the object and its temperature in the entire wavelength range. The radiation temperature sensor is used as the primary instrument

Structure of a radiation pyrometer

(Summary description)The radiation pyrometer is designed and manufactured according to the functional relationship between the radiation energy of the object and its temperature in the entire wavelength range. The radiation temperature sensor is used as the primary instrument

  • Categories:Seminar
  • Author:
  • Origin:
  • Time of issue:2022-03-22 14:08
  • Views:
Information

The radiation pyrometer is designed and manufactured according to the functional relationship between the radiation energy of the object and its temperature in the entire wavelength range. The radiation temperature sensor is used as the primary instrument, and the electronic potentiometer is used as the secondary instrument. It belongs to the lens focusing temperature sensing It has an aluminum alloy casing, the front is an objective lens, a thermopile compensation diaphragm is installed in the casing, and there is a baffle plate on the field diaphragm close to the thermopile. The function of the baffle plate is to adjust the irradiation on the thermopile. The radiant energy of the product makes the product have a uniform index value, and an eyepiece is installed on the detachable rear cover to observe the image of the measured object.

radiation pyrometer from China
The radiation temperature sensor focuses the radiant energy of the object to be measured on the thermal element through the lens, and the thermal element converts the radiant energy into electrical parameters. The thermoelectric potential is generated, and the temperature value is displayed. This temperature value must be corrected by the total radiation black body number of the object or directly inserted into the high-temperature salt bath furnace with a platinum-rhodium 10-platinum thermocouple and a DC potentiometer to measure the temperature, and then measure the temperature with the instrument. A temperature comparison is displayed to calibrate the accuracy of the temperature measured by the pyrometer.

RECOMMEND NEWS

2024
02-20
小黑点

The Role of Dual Wavelength Pyrometer in Energy Conservation

Learn how a dual wavelength pyrometer can revolutionize energy conservation in the instrumentation industry.
查看详情
2024
02-13
小黑点

Understanding Dual Wavelength Pyrometers in Temperature Measurement Instruments

Discover the functionality and benefits of dual wavelength pyrometers in temperature measurement instruments within the field of instrumentation and control, specifically focusing on gas and liquid me
查看详情
2024
02-06
小黑点

Future Trends in Dual Wavelength Pyrometer Technology

Discover the latest advancements in dual wavelength pyrometer technology and how it is shaping the future. From enhanced accuracy to improved usability, this article explores the exciting developments
查看详情
迪凯光电

400-811-6877

Tel:027-8750 9386   027-8750 9105
Add:Dingye building C block, International Enterprise Center, Optics Valley Avenue, Wuhan China  
Fax:027-87745185   
Mail:dkoe@chinadikai.com