Temperature measurement principle of optical pyrometer

News Center

Check category

Temperature measurement principle of optical pyrometer

(Summary description)Any object at high temperature will project a certain wavelength of electromagnetic waves (radiant energy). The visible light with a wavelength of 0.65μm electromagnetic wave is the most sensitive to human eyes, and the radiant energy of this wavelength changes significantly with temperature.

Temperature measurement principle of optical pyrometer

(Summary description)Any object at high temperature will project a certain wavelength of electromagnetic waves (radiant energy). The visible light with a wavelength of 0.65μm electromagnetic wave is the most sensitive to human eyes, and the radiant energy of this wavelength changes significantly with temperature.

Information


Any object at high temperature will project a certain wavelength of electromagnetic waves (radiant energy). The visible light with a wavelength of 0.65μm electromagnetic wave is the most sensitive to human eyes, and the radiant energy of this wavelength changes significantly with temperature. The magnitude of visible light energy is reflected in its perception of the brightness of the human eye. The higher the temperature of the object, the stronger the visible light energy it emits, that is, the brighter the visible light seen.

optical pyrometer china

The method of measuring temperature with an optical pyrometer is to compare the brightness of the measured object at a wavelength of 0.65 μm with the brightness of the filament of the pyrometer powered bulb installed inside the meter. When the brightness of the filament of the meter is the same as the brightness emitted by the object to be measured, it means that The filament temperature is the same as the temperature of the object being measured. Because the brightness of the filament is determined by the current passing through the filament, and each current intensity corresponds to a certain filament temperature, the temperature of the filament can be known by measuring the current, that is, the temperature of the object to be measured. Therefore, this pyrometer is also called a hidden wire optical pyrometer.

However, the optical pyrometer uses human eyes to detect the brightness deviation after all, and also manually adjusts the brightness of the standard lamp to eliminate the deviation to achieve a balanced state of the two (the filament image disappears). Obviously, only when the measured object is high temperature, that is, when the red light band (λ=0.65μm or so) in the radiation light has sufficient intensity, the optical pyrometer can work.

RECOMMEND NEWS

2025
02-04
小黑点

Unlocking Precision: Understanding Dual Wavelength Pyrometers

Discover the intricacies of dual wavelength pyrometers, an essential tool for accurate temperature measurement in various industrial applications. This article provides a comprehensive overview, benef
查看详情
2025
01-28
小黑点

The Art and Science of Temperature Measurement: Dive into Optical Pyrometers

Explore the intricate world of temperature measurement with our comprehensive guide on optical pyrometers. Discover how these advanced instruments operate, their applications across various industries
查看详情
2025
01-21
小黑点

Understanding Aluminum Pyrometers: Instrumentation for Accurate Temperature Measurement

This article explores aluminum pyrometers, detailing their significance in temperature measurement applications, mechanisms of operation, and key considerations for selection and usage in various indu
查看详情
迪凯光电

400-811-6877

Tel:027-8750 9386   027-8750 9105
Add:Dingye building C block, International Enterprise Center, Optics Valley Avenue, Wuhan China  
Fax:027-87745185   
Mail:dkoe@chinadikai.com